Description

WHAT'S IN THE BOX

  • 1x WYLEX LIFELINE 100A 100MA DP TYPE S TIME DELAY RCD (563HV)

NOTES FROM MT EXPERT

Fully Shrouded Terminals

OVERVIEW

WYLEX LIFELINE 100A 100MA DP TYPE S TIME DELAY RCD (563HV)

Suitable for use when total RCD protection is required to supplement the system earthing and where local 30mA RCDs are used to give additional protection. Contact position indication on the dolly handle. Time delay will discriminate with the 30mA RCD.

  • DIN Rail Mounted Fitting
  • Type S Curve
  • Fully Shrouded Terminals
  • 2-Module Size
  • Test Button
Brand Wylex
CSU Device RCDs
Curve Type Type S
Earth Leakage Sensitivity (IDn) 100 mA
Incomer Fitting Type DIN Rail Mounted
Manufacturer Guarantee 1 Year Guarantee
Model Name Lifeline
Model No SFWRMT100/2
No. of Phases Single-Phase
Number of Poles Double Pole
Pack Size 1
Pieces in Pack/Case 1
Product Type Time Delay RCD
Rated Impulse Withstand Voltage (Uimp) 4 kV
Rated Operational Current (In) 100 A
Rated Operational Voltage (Ue) 230 V
Suitable Cable Size 50 mm²
See Full Description
5.0 (120 Reviews)
£82.49 (Inc. VAT)
£68.74 (Ex. VAT)
Adding to cart… The item has been added
We aim to dispatch within 2-3 working days.
Free delivery for UK mainland orders over £250.
Credit plans available. Find out more

Clearpay logo Klarna logo V12 logo

Description

WYLEX LIFELINE 100A 100MA DP TYPE S TIME DELAY RCD

WHAT'S IN THE BOX

  • 1x WYLEX LIFELINE 100A 100MA DP TYPE S TIME DELAY RCD (563HV)

NOTES FROM MT EXPERT

Fully Shrouded Terminals

OVERVIEW

WYLEX LIFELINE 100A 100MA DP TYPE S TIME DELAY RCD (563HV)

Suitable for use when total RCD protection is required to supplement the system earthing and where local 30mA RCDs are used to give additional protection. Contact position indication on the dolly handle. Time delay will discriminate with the 30mA RCD.

  • DIN Rail Mounted Fitting
  • Type S Curve
  • Fully Shrouded Terminals
  • 2-Module Size
  • Test Button
Brand Wylex
CSU Device RCDs
Curve Type Type S
Earth Leakage Sensitivity (IDn) 100 mA
Incomer Fitting Type DIN Rail Mounted
Manufacturer Guarantee 1 Year Guarantee
Model Name Lifeline
Model No SFWRMT100/2
No. of Phases Single-Phase
Number of Poles Double Pole
Pack Size 1
Pieces in Pack/Case 1
Product Type Time Delay RCD
Rated Impulse Withstand Voltage (Uimp) 4 kV
Rated Operational Current (In) 100 A
Rated Operational Voltage (Ue) 230 V
Suitable Cable Size 50 mm²

visa mastercard maestro Paypal Klarna Clearpay Amazon Pay Opayo V12